RFID Interlock Switches

The CES-AP makes transponder technology available to protect even very small guards and doors. The typical CES features such as large read distance and center offset are naturally also offered by the CES-AP. What is more, mounting on profile rails couldn't be easier.

-High protection against tampering
-Category 4 / PL e according to EN ISO 13849-1

-Integrated short circuit monitoring
-Large operating distance

-Connection via plug connectorslogo euchner
-Diagnostics using LED

pdfEuchner RFID Interlock Switch Information5.08 MB

Advantages:

•High protection against tampering
•Category 4 / PL e according to EN ISO 13849-1
•Integrated short circuit monitoring
•Large operating distance
•Connection via plug connectors
•Diagnostics using LED

The CES-AP makes transponder technology available to protect even very small guards and doors. The typical CES features such as large read distance and center offset are naturally also offered by the CES-AP. What is more, mounting on profile rails couldn't be easier.

Design and functionality:

-The safety switch CES-AP… has two safety outputs. These outputs are connected directly to drives, downstream safety relays or safe control systems. The switch monitors itself for short circuits using pulsed signals. External clock signals are therefore not required.

-Indication for actuator in the limit range

-If the safety door with the actuator should settle over time, the actuator can drift out of the read head operating distance. The device recognizes this situation and indicates that the actuator is in the limit range. This allows the safety door to be readjusted in time.

-Connection to safe control systems or safety relays

-Do not use a control system or safety relay with pulsing for monitoring short circuits or switch off the pulsing function in these devices. The switch generates its own clock signals on the output lines OA/OB. A downstream device must tolerate these test pulses, which may have a length of up to 0.4 ms.

-The inputs on the downstream device must be suitable for positive-switching devices (pnp outputs), as the two outputs on the safety switch deliver a level of +24 V in the switched-on state.

OUT output

(depending on version)
The semiconductor output OUT is switched if the safety guard is closed (actuator in the operating distance). It is not allowed to be used for safety functions.

DIA output

(depending on version)
The semiconductor output DIA is switched in the fault state. It is not allowed to be used for safety functions.

Reset inputlogo euchner

(depending on version)
The switch in a fault state can be reset via the RST input. To do this, a voltage of 24 V is applied to the RST input for at least 3 seconds. It is not necessary to disconnect the supply of power to reset a fault.

pdfEuchner RFID Interlock Switch Information5.08 MB
  • In Iowa:

    Toll Free: (800) 328-6236
    Phone: (515) 225-6933
    Fax: (515) 225-0063

    1207 Maple Street
    P.O. Box 65310
    West Des Moines, Iowa 50265   (map)
    In Nebraska:

    Toll Free: (888) 304-7629
    Phone: (402) 467-4041
    Fax: (402) 467-4072

    5900 N. 58th Street, Suite 2
    Lincoln, Nebraska 68507   (map)
    In Kansas & Missouri:

    Phone: (816) 256-4142
captcha