Optex CD2H-130 Digital Laser 130mm ±70mm, Analog, NPN/PNP IO-LINK 2m Cable
Item #:
CD2H-130
Product Info
Optex FA
Optex Digital Displacement Measurement Laser With IO-LINK Compatibility
- OLE Digital Display with Measurement Range of 130mm ±70mm
- FDA Class 1 Laser features ø0.3 mm beam spot with 4µm repeat accuracy
- 2CH Output: NPN, PNP, Analog, IO-LINK (COM3)
- Eight Selectable Sampling Cycles (Fastest: 133.3µs)
- 2m Connection Cable
Item Specifications
-
CD2H
-
Laser Displacement Reflective
-
Sensor Self-Contained
-
Visible Red Laser Beam
-
Red Semiconductor Laser, Wavelength 655nm, 390µW Max Output, Class 1 IEC/JIC, Contact Ramco for FDA
-
Diffuse
-
Small beam spot
-
Ø 0.3mm
-
130mm ±70mm
-
4.0µm
-
18 to 24 VDC
-
133.3µs
-
See Sample Rate
-
Easy-to-read OLED for menu text in 7 languages. Recieved light values display in numeric value, graph, or waveform. Note: sensor has warmup time of 30 minutes
-
IO-Link, Digital, Analog
-
IO-Link (COM3 230.4kbps) NPN/PNP open collector or Push-Pull (selectable by setting) 100mA/24VDC
-
4 to 20mA and 0 to 10VDC
-
IO-LINK process date 6 bytes, cycle time is 0.7ms
-
–10 to +50° C
-
PBT enclosure, PMMA front window
-
IP67
-
Cable
-
2 meter cable
-
0.40 lbs per EA