Optex CD2H-700-485M122 Digital Laser 700mm ±500mm, RS-485, NPN/PNP, 300 Pigtail w/M12 5P
Item #:
CD2H-700-485M122
Product Info
Optex FA
Optex Digital Displacement Measurement Laser With RS-485 half-duplex communication
- OLE Digital Display with Measurement Range of 700mm ±500mm
- FDA Class 2 Laser features ø1.0 mm beam spot with 100µm repeat accuracy
- Modbus RTU Protocol
- NPN/PNP or Push-Pull Output
- Eight Selectable Sampling Cycles (Fastest: 133.3µs)
- 300mm Pigtail with M12 5 Pin connecotor
Item Specifications
-
CD2H
-
Laser Displacement Reflective
-
Sensor Self-Contained
-
Visible Red Laser Beam
-
Red Semiconductor Laser, Wavelength 655nm, 1mW Max Output, Class 2 IEC/JIC, Contact Ramco for FDA
-
Diffuse
-
Small beam spot
-
Ø 1.0mm
-
700mm ±500mm
-
100µm
-
18 to 24 VDC
-
133.3µs
-
See Sample Rate
-
Easy-to-read OLED for menu text in 7 languages. Recieved light values display in numeric value, graph, or waveform. Note: sensor has warmup time of 30 minutes
-
Digital, Serial
-
NPN/PNP open collector or Push-Pull (selectable by setting) 100mA/24VDC
-
RS-485
-
–10 to +50° C
-
PBT enclosure, PMMA front window
-
IP67
-
Quick disconnect
-
Pigtail 300mm with M12 5 pin male connector
-
1.00 lbs per EA