Optex CD33-L85CN-422 Specular 82.9mm ±10mm, 2ch NPN / RS-422, QD
Product Info
Glass Thickness
The serial output version along with the software has the ability to measure glass thickness by calcualting the distance from 1st surface of glass to the bottom surface
RS422 Serial Output Version
RS-422 version provides digital output of measurement data over serial communications. There is a basic software application for communicating with the sensor via PC. The serial version
can also be connected directly to the Melsec-Q series PLC when using the UQ1 controller. This controller provides an automatic and simple interface to the PLC. The best solution for measurement applications when using Mitsubishi Q series PLC.
Compact Size Ideal for Mounting on End Effectors
Ideal for mounting on robotic cylinder thanks to compact dimensions and light weight. IP67 water tightness is also secured.
High Resolution Electronic Shutter
High resolution electronic shtter controls to keep a constant level according to reflection. This function enables stable peak level detection
even when unstable surface conditions exist.
Digital Subpixel Processing
Subpixel processing divides one pixel into small pieces that enables accurate measurement
by reproducing genuine value of incoming light
Item Specifications
-
CD33L
-
Laser Displacement Reflective
-
Sensor Self-Contained
-
Visible Red Laser Beam
-
Red Semiconductor Laser, Wavelength 655nm, 390mW Max Output, Class II FDA, Class 1 IEC/JIS
-
Specular
-
Small beam spot
-
0.1 x 0.1mm at 85mm
-
82.9mm ±10mm
-
5.0µm
-
12 to 24VDC
-
0.5ms
-
5.0ms
-
LED bar graph indication for easy installation at desired distance. PB setting for digital ouput(s) units w/multi-function input: remote teach, sample hold, laser off. SENSOR WARM-UP TIME 15 MIn
-
Digital, Serial
-
1 each NPN
-
RS-422
-
–10 to +45° C
-
PBT
-
IP67
-
Quick disconnect
-
Connector (swivel type) M12 8 pin male