Optex CD5-W30A Laser Measurement 25 to 35mm Range Wide Beam American Version
Product Info
Digital Sub-Pixel Processing
The linearity has been improved to more than twice that of a conventional product by digital sub-pixel processing.
This divides one pixel into 65536 sub-pixels providing accurate profile reproduction.
Uneven Surface Correction
Even if the object is translucent or its surface is eneven, it can detect the position
of the true peak thanks to a custom algorithm designed by Optex
Cross Talk Prevention
Cross talk prevention function eliminates interference between 2 sensor even when the beams are crossing or are mounted close together.
Wide Spot Beam for Increased Stability
The wide beam spot type can measure rough surfaces with a high degreee of linearity and stability.
Diffuse and Specular Mode
When specular mode is selected the sensor can measure 1st surface of transparent material and can even detect
glass thickness using the glass thickness measurement algorithm
Item Specifications
-
CD5
-
Laser Displacement Reflective
-
Sensor Less Controller
-
Visible Red Laser Beam
-
Red Semiconductor Laser, Wavelength 650nm, 1mW Max Output, Class II FDA, Class 2 IEC/JIS
-
Diffuse or Specular
-
Wide beam
-
260 x 1000µm at 30mm
-
30mm ±5mm
-
0.46µm
-
12 to 24VDC
-
100µs
-
See Sample Rate
-
DIN mountable and accepts up to three CD5-__ heads. 16 Channel bank function. LCD displays values, lightwave form. Calculation functions that include addition, subtraction, and off-setting.
-
Sensor head features RS-422 serial interface and can be used without CD5A controller. Some Diffuse types can be mounted for specular and transparent targets, WARM-UP TIME 30 MINUTES
-
Digital, Analog, Serial, USB
-
See CD5 Series Controller Specification
-
See CD5 Series Controller Specification
-
See CD5 Series Controller Specification
-
–10 to +50° C
-
Die-cast Aluminum enclosure, glass lens
-
IP67
-
Quick disconnect
-
Pigtail 500mm with Optex DOL/DSL male connector
-
0.10 lbs per EA