Optex CD5-W500 Laser Measurement 300 to 700mm Range Wide Beam
Item #:
CD5-W500
Product Info
Optex FA
Digital Sub-Pixel Processing
The linearity has been improved to more than twice that of a conventional product by digital sub-pixel processing.
This divides one pixel into 65536 sub-pixels providing accurate profile reproduction.
Uneven Surface Correction
Even if the object is translucent or its surface is eneven, it can detect the position
of the true peak thanks to a custom algorithm designed by Optex
Cross Talk Prevention
Cross talk prevention function eliminates interference between 2 sensor even when the beams are crossing or are mounted close together.
Wide Spot Beam for Increased Stability
The wide beam spot type can measure rough surfaces with a high degreee of linearity and stability.
Item Specifications
-
CD5
-
Laser Displacement Reflective
-
Sensor Less Controller
-
Visible Red Laser Beam
-
Red Semiconductor Laser, Wavelength 658nm, 1mW Max Output, Class II FDA, Class 2 IEC/JIS
-
Diffuse
-
Wide beam
-
1000 x 3700µm at 500mm
-
500mm ±200mm
-
10µm
-
12 to 24VDC
-
100µs
-
See Sample Rate
-
DIN mountable and accepts up to three CD5-__ heads. 16 Channel bank function. LCD displays values, lightwave form. Calculation functions that include addition, subtraction, and off-setting.
-
Sensor head features RS-422 serial interface and can be used without CD5A controller. Some Diffuse types can be mounted for specular and transparent targets, WARM-UP TIME 30 MINUTES
-
Digital, Analog, Serial, USB
-
See CD5 Series Controller Specification
-
See CD5 Series Controller Specification
-
See CD5 Series Controller Specification
-
–10 to +50° C
-
Die-cast Aluminum enclosure, glass lens
-
IP67
-
Quick disconnect
-
Pigtail 500mm with Optex DOL/DSL male connector
-
0.10 lbs per EA