Banner QS18 Demo: Auto Compensation and 30ms Off Delay
In this article and demonstration, we will walk you through some of the advanced configuration features of the QS18 clear object sensor from Banner engineering. You will learn how to enable the auto compensation feature as well as how to enable the 30 ms off delay. Let’s take a look!
The auto compensation feature will automatically compensates for the effects of dust and ambient temperature changes. This feature is set to off by default. To enable this feature, press and hold the push button for 2 seconds. Click the push button 3 times to enter into the advanced configuration menu. the green and amber LEDs will flash simultaneously at 1hz to indicate that you have entered this menu. click the push button 3 times to enable the auto compensation feature. The green and amber LEDs will flash 3 times followed by the acceptance flash.
If you choose To disable this feature once it has been enabled, follow steps 1 & 2 at step three, click the push button 4 times to disable the auto compensation setting. The green and amber LEDs will flash 4 times followed by the acceptance flash.
To enable the 30 ms off delay press and hold the push button for 2 seconds. Click the button 3 times to enter the advanced menu. click the button 5 times to enable the off delay the green and amber LEDs will flash 5 times followed by the acceptance flash.
To disable the off delay once it has been enabled, follow steps 1 and 2 but on step 3 click the button 6 times to disable the off delay.
Learn more about the QS18 Clear Object Detection Sensor.
Learn how to set up Light set, Dark set, and 3 offset settings on your QS18.